Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare180 MVA 345/34.5 kV Georgia TransformerJJ-TX-003345/34.5 kV Transformer Production PositionsJJ-TX-204
ManufacturerGeorgia TransformerManufacturer disclosed in the qualified technical package
Rating / output108/144/180 MVA; 37.8/50.4/63 MVA tertiary266 MVA offered; final rating requires reconciliation
Voltage / winding arrangement345/34.5 kV with 12 kV buried-delta tertiary345 kV HV / 34.5 kV LV
Vector groupYNyn0+d1Requires confirmation
FrequencyNot documented; confirm with J&J60 Hz
CoolingNot documented; confirm with J&JNot documented; confirm with J&J
Impedance and baseNot documented; confirm with J&JNot documented; confirm with J&J
Tap changerNot documented; confirm with J&JNot documented; confirm with J&J
Insulation / BILNot documented; confirm with J&JNot documented; confirm with J&J
Quantity represented1 documented unit2 offered positions
Technical details / open itemsONAN/ONAF1/ONAF2, 60 Hz, three-phase, vector group YNyn0+d1; Measured H-X impedance: 6.99% on a 108 MVA base; Factory test report concludes results were within technical tolerancesSeller offer summary; exact cooling stages require confirmation.; Ask J&J for the included U.S.-port shipping, commissioning and manufacturer warranty scope in the written offer.; Modifications can be reviewed before completion; feasibility, cost and schedule impact require OEM confirmation.; Any warranty provider, scope, transfer eligibility, start date and commissioning boundary must appear in the written quotation.; The offered summary states 266 MVA. Supplied outlines include different 226 MVA and 266 MVA designs without a confirmed match to each position. Resolve the individual nameplate and design before technical acceptance.
Evidence reviewedSerial-specific approval drawings and FAT report reviewedSeller offer summary; exact cooling stages require confirmation
Technical value basisSerial-specific approval drawings and FAT report reviewedReceived production offer and existing reviewed design package; final individual nameplates and factory tests remain pending.
Details to confirmMatching technical records, current condition, complete equipment scope and transport detailsMatch the final design/rating and drawing revision to each offered manufacturing position; Final frequency, cooling/rise, winding duty, impedance/base, BIL, taps, accessories and transport dimensions/weights
Represented conditionBrand new, never used and never energized; factory acceptance tested September 2024Factory manufacturing position; completion pending
Equipment locationUSADispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable for sale — confirmed by J&J October 8, 2026; quotation and release terms on request2027 manufacturing positions offered for allocation; current release terms require written confirmation
Availability last confirmed2026-10-08Request current confirmation
Shipping estimateRequest a written dispatch and delivery scheduleProjected 2027 completion; shipment and receiving dates require written confirmation
Nameplate reviewedNot recorded as reviewed; request itNot recorded as reviewed; request it
Drawings reviewedYes — request matching unit drawingsNot recorded as reviewed; request them
Factory test report reviewedReport reviewed; confirm matching records for each unitNot recorded as reviewed; request test records
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist