Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare220 MVA 345/34.5 kV Prolec GE TransformerJJ-TX-002345/34.5 kV Transformer Production PositionsJJ-TX-204
ManufacturerProlec GEManufacturer disclosed in the qualified technical package
Rating / output132/176/220 MVA; 46.2/61.6/77 MVA tertiary266 MVA offered; final rating requires reconciliation
Voltage / winding arrangement345/34.5 kV with 13.8 kV delta tertiary345 kV HV / 34.5 kV LV
Vector groupGrounded Wye–Wye / Delta; clock to confirmRequires confirmation
Frequency60 Hz60 Hz
CoolingONAN / ONAF / ONAFNot documented; confirm with J&J
Impedance and baseDesign H–X: 12.0% at 132 MVANot documented; confirm with J&J
Tap changerNot documented; confirm with J&JNot documented; confirm with J&J
Insulation / BILNot documented; confirm with J&JNot documented; confirm with J&J
Quantity represented1 documented unit2 offered positions
Technical details / open itemsCollector step-up duty; ONAN/ONAF/ONAF, 60 Hz, three-phase; Grounded-wye / grounded-wye / delta winding configuration; Nominal design H-X impedance: 12.0% on a 132 MVA baseSeller offer summary; exact cooling stages require confirmation.; Ask J&J for the included U.S.-port shipping, commissioning and manufacturer warranty scope in the written offer.; Modifications can be reviewed before completion; feasibility, cost and schedule impact require OEM confirmation.; Any warranty provider, scope, transfer eligibility, start date and commissioning boundary must appear in the written quotation.; The offered summary states 266 MVA. Supplied outlines include different 226 MVA and 266 MVA designs without a confirmed match to each position. Resolve the individual nameplate and design before technical acceptance.
Evidence reviewedSerial-specific nameplate and approval drawings reviewedSeller offer summary; exact cooling stages require confirmation
Technical value basisSupplied nameplate and approval drawings; design values require matching final factory records.Received production offer and existing reviewed design package; final individual nameplates and factory tests remain pending.
Details to confirmFinal tested impedance, insulation levels, complete tap schedule and approved drawing revision; Overall and shipping dimensions, shipping weight, accessory schedule and current preservationMatch the final design/rating and drawing revision to each offered manufacturing position; Final frequency, cooling/rise, winding duty, impedance/base, BIL, taps, accessories and transport dimensions/weights
Represented conditionBrand new, never used and never energized; approval drawings reviewedFactory manufacturing position; completion pending
Equipment locationUSADispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; nameplate and approval drawings reviewed; subject to prior sale and written confirmation2027 manufacturing positions offered for allocation; current release terms require written confirmation
Availability last confirmed2026-09-24Request current confirmation
Shipping estimateRequest a written dispatch and delivery scheduleProjected 2027 completion; shipment and receiving dates require written confirmation
Nameplate reviewedYes — request the unit packageNot recorded as reviewed; request it
Drawings reviewedYes — request matching unit drawingsNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist

Call Email Sales