Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare300 MVA 138/34.5 kV Georgia TransformerJJ-TX-00142 MVA 138/34.5 kV Virginia TransformerJJ-TX-102
ManufacturerGeorgia TransformerVirginia Transformer
Rating / output180/240/300 MVA; 63/84/105 MVA tertiary25.2/33.6/42 MVA
Voltage / winding arrangement138/34.5 kV with 12 kV buried-delta tertiary138/34.5 kV
Vector groupYNyn0+d1Winding connections and phase shift to confirm
FrequencyNot documented; confirm with J&JNot documented; confirm with J&J
CoolingNot documented; confirm with J&JNot documented; confirm with J&J
Impedance and baseNot documented; confirm with J&JNot documented; confirm with J&J
Tap changerNot documented; confirm with J&JNot documented; confirm with J&J
Insulation / BILNot documented; confirm with J&JNot documented; confirm with J&J
Quantity represented1 documented unit1 schedule entry; individual identity to confirm
Technical details / open itemsONAN/ONAF/ONAF, 60 Hz, three-phase, vector group YNyn0+d1; Measured 138/34.5 kV impedance: 9.67% on a 180 MVA base; Copper windings, conservator system, Type II mineral oil, and HV OLTCRatings and manufacturer are transcribed from the J&J-submitted schedule; verify them against the matching nameplate and current technical package.; Service history, present condition, frequency, winding arrangement, impedance, tap changer and accessories require unit-specific confirmation.; Historical schedule dates do not establish current dispatch timing, manufacture year or transferable warranty. Request present release terms and any applicable warranty in writing.
Evidence reviewedSerial-specific nameplate reviewedJ&J-submitted inventory schedule; matching unit-specific technical records to confirm
Technical value basisSerial-specific nameplate reviewedSubmitted inventory schedule; manufacturer and electrical rating are representations, not an individual nameplate match.
Details to confirmMatching technical records, current condition, complete equipment scope and transport detailsIndividual identity and quantity, current photos, condition/service history and preservation; Frequency, cooling/rise, winding connections and clock, impedance/base, BIL, conductor/fluid and tap schedule; Factory/current tests, included accessories, dimensions/weights and final release/transport scope
Represented conditionBrand new, never used and never energized; 2020 nameplate reviewedCondition and service history require confirmation
Equipment locationUSALocation confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable for sale — confirmed by J&J October 8, 2026; quotation and release terms on requestListed for inquiry by J&J; current allocation and release timing require written confirmation
Availability last confirmed2026-10-08Request current confirmation
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageNot recorded as reviewed; request it
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist