Your equipment shortlist
Compare equipment before you request it.
Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.
| Compare | GE LM6000 PD SPRINT 46 MW Cogeneration PlantJJ-TUR-006 | GE LM2500 G4 36.1 MW Gas Turbine PackageJJ-TUR-003 |
|---|---|---|
| Manufacturer | GE | GE |
| Rating / output | 46 MW reported output | 36.1 MW reported output |
| Voltage / winding arrangement | 11.5 kV | Generator voltage to confirm |
| Vector group | Not applicable; generator connection to confirm | Not applicable; generator connection to confirm |
| Frequency | 50 Hz | Frequency to confirm |
| Cooling | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Impedance and base | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Tap changer | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Insulation / BIL | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Quantity represented | 1 offered plant | 1 offered package |
| Technical details / open items | The supplied technical package lists a Brush generator rated 50.8 MW / 63.5 MVA at 11.5 kV, 50 Hz, 0.8 power factor. That generator rating is separate from the offered 46 MW plant rating.; Reported HRSG duty: 52 t/hr, 103 barg, 313°C; confirm the actual steam performance and current equipment condition.; The package lists a Lufkin gearbox, Woodward/MicroNet controls, Bently Nevada monitoring and ABB DCS; confirm included configurations and revisions.; The technical package reports a December 2024 GE inspection and serviceable borescope findings; request the underlying report and current inspection.; Dismantling is required; included scope, isolation, removal, packing and transport must be agreed.; Confirm net output, steam duty, operating history, current condition and release schedule. | Request matching turbine and generator records, maintenance history and package drawings.; Do not combine this single 36.1 MW position with the two 33.6 MW LM2500+G4 packages.; Current availability and delivery require written reconfirmation. |
| Evidence reviewed | Written equipment offer; unit-specific technical records and identity to confirm | Written equipment offer; unit-specific technical records and identity to confirm |
| Technical value basis | Received equipment offer; ratings, history and scope are representations until matched to the selected package. | Received equipment offer; ratings, history and scope are representations until matched to the selected package. |
| Details to confirm | Current hours/starts, overhaul and inspection records, actual fuel/emissions and net output/steam duty; Matching generator/breaker ratings, final scope, dismantling, isolation, packing and loading responsibilities | Matching engine/turbine and generator nameplates, individual hours/starts, maintenance/overhaul records and current tests; Electrical duty, site-output basis, fuel/emissions, complete auxiliaries and loading/dismantling/transport scope |
| Represented condition | Used; factory-refurbished engine reportedly installed in 2021 | 2011 manufacture reported; condition and hours to confirm |
| Equipment location | Location confirmed with quotation | Location confirmed with quotation |
| Technical records reviewed | 2026-10-08 | 2026-10-08 |
| Availability | Offered subject to prior sale; current availability and release schedule to confirm | Offered subject to prior sale; current availability and release schedule to confirm |
| Availability last confirmed | Request current confirmation | Request current confirmation |
| Shipping estimate | Request a written dispatch and delivery schedule | Request a written dispatch and delivery schedule |
| Nameplate reviewed | Not recorded as reviewed; request it | Not recorded as reviewed; request it |
| Drawings reviewed | Not recorded as reviewed; request them | Not recorded as reviewed; request them |
| Factory test report reviewed | Not recorded as reviewed; request test records | Not recorded as reviewed; request test records |
| This unit only | Request more info | Request more info |
One request
Request Availability for Your Shortlist.
Email Tommy to discuss these options. The listing IDs will already be in the email subject.
What still needs to be checked?
Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.
Match the nameplate to the specification · Review surplus equipment records · Procurement checklist