Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
CompareILJIN 167 MVA 230/34.5 kV New / Unused TransformerJJ-ILJIN-230-16788 MVA 230/34.5 kV WEG Power TransformerJJ-WEG-230-88
ManufacturerILJIN ElectricWEG
Rating / output100/133/167 MVA53/70.5/88 MVA; 18.55/24.675/30.8 MVA tertiary
Voltage / winding arrangement230/34.5 kV; tertiary voltage to confirm230/34.5 kV with 13.8 kV stabilizing delta tertiary
Vector groupYNyn0+d represented; tertiary clock to confirmYNyn0d1
FrequencyNot documented; confirm with J&J60 Hz
CoolingNot documented; confirm with J&JONAN / ONAF1 / ONAF2
Impedance and baseNot documented; confirm with J&JNot documented; confirm with J&J
Tap changerNot documented; confirm with J&JHV OLTC; 207–253 kV (±10%); 16 raise / 16 lower steps of 0.625%
Insulation / BILNot documented; confirm with J&JNot documented; confirm with J&J
Quantity represented1 represented unit1 nameplate-documented unit
Technical details / open itemsThe individual August offer expressly identifies this ILJIN option as new/unused and never energized; that offer was forwarded again September 30, 2026.; A separate September 30 equipment table repeats 100/133/167 MVA and 230/34.5 kV. Dispatch location and allocation require current confirmation through J&J.; The supplied vector description is YNyn0+d. Obtain the individual nameplate, tertiary rating and voltage, vector clock, frequency, cooling stages and test records before duty approval.; Confirm preservation and storage history, actual warranty provider and transferable written coverage, loading and shipping terms with the quotation.; This ILJIN offer is distinct from the separately listed Fortune Electric 167 MVA transformer; no additional Fortune unit is implied.Three-phase, 60 Hz, ONAN/ONAF1/ONAF2, vector group YNyn0d1; 230 kV grounded-wye primary, 34.5 kV grounded-wye secondary, and 13.8 kV stabilizing delta tertiary; HV LTC represented at plus/minus 10% with 16 raise and 16 lower steps; 2020 manufacture shown on the reviewed nameplate drawing
Evidence reviewedIndividual written offer, repeated in a September 30 equipment listingSerial-specific nameplate drawing reviewed
Technical value basisReceived written equipment offer; individual technical records require review.Supplied approval nameplate drawing; the impedance field is not completed.
Details to confirmIndividual nameplate, frequency, cooling/rise, tertiary duty and vector clock; Impedance/base, BIL, taps, copper/fluid specification, factory tests, preservation and transport scopeFinal tested impedance/base, all winding/bushing BIL levels and oil quantity; Matching factory tests, current preservation, final dimensions and complete accessories
Represented conditionNew / unused and never energized, as explicitly represented in the offerBrand new, never used and never energized; 2020 nameplate reviewed
Equipment locationInternational; dispatch location confirmed with quotationUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityListed in received September 30, 2026 offers; current allocation, condition and dispatch timing require written confirmationAvailable; nameplate drawing reviewed; subject to prior sale and written reconfirmation
Availability last confirmedRequest current confirmation2026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.