Your equipment shortlist
Compare equipment before you request it.
Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.
| Compare | ILJIN 167 MVA 230/34.5 kV New / Unused TransformerJJ-ILJIN-230-167 | 88 MVA 230/34.5 kV WEG Power TransformerJJ-WEG-230-88 |
|---|---|---|
| Manufacturer | ILJIN Electric | WEG |
| Rating / output | 100/133/167 MVA | 53/70.5/88 MVA; 18.55/24.675/30.8 MVA tertiary |
| Voltage / winding arrangement | 230/34.5 kV; tertiary voltage to confirm | 230/34.5 kV with 13.8 kV stabilizing delta tertiary |
| Vector group | YNyn0+d represented; tertiary clock to confirm | YNyn0d1 |
| Frequency | Not documented; confirm with J&J | 60 Hz |
| Cooling | Not documented; confirm with J&J | ONAN / ONAF1 / ONAF2 |
| Impedance and base | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Tap changer | Not documented; confirm with J&J | HV OLTC; 207–253 kV (±10%); 16 raise / 16 lower steps of 0.625% |
| Insulation / BIL | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Quantity represented | 1 represented unit | 1 nameplate-documented unit |
| Technical details / open items | The individual August offer expressly identifies this ILJIN option as new/unused and never energized; that offer was forwarded again September 30, 2026.; A separate September 30 equipment table repeats 100/133/167 MVA and 230/34.5 kV. Dispatch location and allocation require current confirmation through J&J.; The supplied vector description is YNyn0+d. Obtain the individual nameplate, tertiary rating and voltage, vector clock, frequency, cooling stages and test records before duty approval.; Confirm preservation and storage history, actual warranty provider and transferable written coverage, loading and shipping terms with the quotation.; This ILJIN offer is distinct from the separately listed Fortune Electric 167 MVA transformer; no additional Fortune unit is implied. | Three-phase, 60 Hz, ONAN/ONAF1/ONAF2, vector group YNyn0d1; 230 kV grounded-wye primary, 34.5 kV grounded-wye secondary, and 13.8 kV stabilizing delta tertiary; HV LTC represented at plus/minus 10% with 16 raise and 16 lower steps; 2020 manufacture shown on the reviewed nameplate drawing |
| Evidence reviewed | Individual written offer, repeated in a September 30 equipment listing | Serial-specific nameplate drawing reviewed |
| Technical value basis | Received written equipment offer; individual technical records require review. | Supplied approval nameplate drawing; the impedance field is not completed. |
| Details to confirm | Individual nameplate, frequency, cooling/rise, tertiary duty and vector clock; Impedance/base, BIL, taps, copper/fluid specification, factory tests, preservation and transport scope | Final tested impedance/base, all winding/bushing BIL levels and oil quantity; Matching factory tests, current preservation, final dimensions and complete accessories |
| Represented condition | New / unused and never energized, as explicitly represented in the offer | Brand new, never used and never energized; 2020 nameplate reviewed |
| Equipment location | International; dispatch location confirmed with quotation | USA |
| Technical records reviewed | 2026-10-08 | 2026-10-08 |
| Availability | Listed in received September 30, 2026 offers; current allocation, condition and dispatch timing require written confirmation | Available; nameplate drawing reviewed; subject to prior sale and written reconfirmation |
| Availability last confirmed | Request current confirmation | 2026-09-24 |
| Shipping estimate | Request a written dispatch and delivery schedule | Request a written dispatch and delivery schedule |
| Nameplate reviewed | Not recorded as reviewed; request it | Yes — request the unit package |
| Drawings reviewed | Not recorded as reviewed; request them | Yes — request matching unit drawings |
| Factory test report reviewed | Not recorded as reviewed; request test records | Not recorded as reviewed; request test records |
| This unit only | Email for specs & price | Email for specs & price |
One request
Request Availability for Your Shortlist.
Email Tommy to discuss these options. The listing IDs will already be in the email subject.
What still needs to be checked?
Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.
Match the nameplate to the specification · Review surplus equipment records · Procurement checklist