Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
CompareILJIN 167 MVA 230/34.5 kV New / Unused TransformerJJ-ILJIN-230-167New 220 MVA 230/34.5 kV ABB/Hitachi TransformerJJ-230-220-1
ManufacturerILJIN ElectricABB / Hitachi
Rating / output100/133/167 MVA132/176/220 MVA
Voltage / winding arrangement230/34.5 kV; tertiary voltage to confirm230/34.5 kV with 13.8 kV buried-delta tertiary
Vector groupYNyn0+d represented; tertiary clock to confirmYNyn0d1 — Wye–Wye / Delta
FrequencyNot documented; confirm with J&J60 Hz
CoolingNot documented; confirm with J&JONAN / ONAF / ODAF
Impedance and baseNot documented; confirm with J&JH–X: 10.47% at 132 MVA, 230/34.5 kV
Tap changerNot documented; confirm with J&JHV OLTC; nameplate tap table spans 205.8–254.2 kV; confirm the selected tap and final switch schedule
Insulation / BILNot documented; confirm with J&JHV line 900 kV; HV neutral, LV and tertiary 200 kV
Quantity represented1 represented unit1 unit
Technical details / open itemsThe individual August offer expressly identifies this ILJIN option as new/unused and never energized; that offer was forwarded again September 30, 2026.; A separate September 30 equipment table repeats 100/133/167 MVA and 230/34.5 kV. Dispatch location and allocation require current confirmation through J&J.; The supplied vector description is YNyn0+d. Obtain the individual nameplate, tertiary rating and voltage, vector clock, frequency, cooling stages and test records before duty approval.; Confirm preservation and storage history, actual warranty provider and transferable written coverage, loading and shipping terms with the quotation.; This ILJIN offer is distinct from the separately listed Fortune Electric 167 MVA transformer; no additional Fortune unit is implied.132/176/220 MVA, 230 kV grounded-wye high side and 34.5 kV grounded-wye low side; YNyn0d1 connection documented in the manufacturer factory test report; 13.8 kV buried-delta tertiary; 2021 ABB rating-plate drawing; three-phase, 60 Hz, ONAN/ONAF/ODAF cooling; Contact Tommy Marco directly for the technical package, price, and delivery arrangements; Nameplate impedance: 10.47% on a 132 MVA, 230/34.5 kV base; final configuration confirmed with the technical package
Evidence reviewedIndividual written offer, repeated in a September 30 equipment listingManufacturer nameplate and factory test report reviewed
Technical value basisReceived written equipment offer; individual technical records require review.Supplied unit nameplate and historical factory photograph; current inspection and matching factory records remain necessary.
Details to confirmIndividual nameplate, frequency, cooling/rise, tertiary duty and vector clock; Impedance/base, BIL, taps, copper/fluid specification, factory tests, preservation and transport scopeCurrent preservation, complete factory-test reports and included accessory schedule; Overall/shipping dimensions, shipping weight, oil quantity and loading arrangements
Represented conditionNew / unused and never energized, as explicitly represented in the offerBrand new, never used and never energized
Equipment locationInternational; dispatch location confirmed with quotationUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityListed in received September 30, 2026 offers; current allocation, condition and dispatch timing require written confirmationAvailable; confirmed by J&J on September 24, 2026; subject to prior sale and written confirmation
Availability last confirmedRequest current confirmation2026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist