Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
CompareHICO 140 MVA 235/34.5/13.8 kV Transformer PairJJ-HICO-235-140-2Royal SMIT 525/69 kV Transformers — 3 AvailableJJ-SMIT-525-3
ManufacturerHICORoyal SMIT
Rating / output85/115/140 MVA240/320/400 MVA; 250 MVA maximum step-down; 90 MVA tertiary
Voltage / winding arrangement235/34.5/13.8 kV525/69 kV with 13.7 kV buried-delta tertiary
Vector groupWinding connections and vector clock to confirmYNyn0(d1) — Wye–Wye / buried Delta
FrequencyNot documented; confirm with J&J60 Hz
CoolingONAN / ONAF1 / ONAF2 representedONAN / ONAF / ONAF
Impedance and baseNot documented; confirm with J&JH–X: 12.90% at 240 MVA, 525/69 kV, 85°C
Tap changerNot documented; confirm with J&JHV OLTC; 472.5–577.5 kV (±10%); 16 raise / 16 lower steps of 0.625%
Insulation / BILNot documented; confirm with J&JHV winding 1550 kV / bushing 1675 kV; LV 350 kV; tertiary 150 kV
Quantity represented2 represented matching units3 units
Technical details / open itemsThe received offer represents a matching pair at 85/115/140 MVA, 235/34.5/13.8 kV, with copper windings, three phases and ONAN/ONAF1/ONAF2 cooling.; The exact offered high-side rating is 235 kV. Compatibility with a 230 kV project must be established from the actual nameplates, taps, insulation and project requirements.; An early-October arrival in the United States was scheduled in the earlier offer. Arrival has not been confirmed and the units are not described as immediately available U.S. stock.; Individual condition and service history are unresolved; the pair is excluded from the new/unused and used/pre-owned filters until confirmed.; Request both individual nameplates, frequency, winding connections, tertiary duty, tests, preservation/service records, arrival evidence and written purchase and warranty terms.Three units offered for allocation; availability and 4–8 week shipping schedule confirmed by J&J on October 1, 2026.; Nameplate rating: 240/320/400 MVA with ONAN/ONAF/ONAF cooling. Maximum stated duty: 400 MVA step-up or 250 MVA step-down.; Three-phase, 60 Hz; 525 kV grounded-wye high side, 69 kV wye low side, and 13.7 kV buried-delta tertiary rated 90 MVA.; Copper windings; MR on-load tap changer; HV tap range 472.5–577.5 kV (±10%).; HV BIL: 1550 kV winding / 1675 kV bushing. LV BIL: 350 kV.; Nameplate H-X impedance: 12.90% at 240 MVA base, 525/69 kV, 85°C.; Supplied 2022 factory acceptance test report records Passed for the documented unit. Nameplate, outline drawing and test report available through J&J; match the records to all three units before purchase.
Evidence reviewedReceived written offer for a matching pairSupplied nameplate, outline drawing and factory acceptance test report
Technical value basisWritten offer for a matching pair; confirm both actual nameplates.Supplied nameplate for one documented unit; match the complete package to each of the three offered units.
Details to confirmBoth nameplates, current condition/arrival, frequency, rise, connections and tertiary duty; Impedance/base, BIL, taps, factory/service tests, preservation, dimensions/weights and accessoriesMatching records for each offered unit, current condition, included accessories and transport scope; Unit-specific factory tests, present preservation and the step-down duty limit
Represented conditionIndividual condition and service history require confirmation2022 manufacture shown in supplied nameplate; condition and service history confirmed with quotation
Equipment locationLocation confirmed with quotationInternational; dispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityEarly-October 2026 U.S. arrival was scheduled in the received offer; arrival and present allocation are unconfirmedImmediately available; estimated 4–8 weeks to ship; subject to prior sale
Availability last confirmedRequest current confirmation2026-10-01
Shipping estimateRequest a written dispatch and delivery schedule4–8 weeks to ship
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist

Call Email Sales